SD33-85-485-VA

SD33-85
SD33-85
SD33-85
  • SD33-85
  • SD33-85
  • SD33-85

SD33-85

Product Introduction

Reference distance: 15 mm

Measurement range: ±5 mm

Repeatability: 20 μm

Spot size: 50 × 200 μm

Sampling frequency: selectable 300 / 500 / 1000 / 2000 / 3000 Hz

Laser output power: 1 mW



Download related documents
Contact Now price

Technical specifications

Model

SD33-50

Reference distance (RF)

85mm

Measuring range

±15mm

Light source

Light source wavelength

655nm

Laser class

Class II

Laser output power

1mW

Laser point diameter (Laser dot size)

Near-end

150*600μm

Reference distance

140*990μm

Far-end

190*12000μm

Repeatability

10μm

Linearity

±0.05% F.S.

Temperature characteristics

0.05% F.S./℃

Sampling refresh rate (Hz)

500/1000/2000/3000Hz (Choose from four levels)

I/O

Communication port

1 RS485

Analog output

1 channel analog output, analog voltage (0~10V) or analog current (4~20mA)

Analog voltage or current cannot be switched

IO input

1 channel, supports functions, such as laser shutdown, remote teaching, sampling and holding, single-pulse trigger, zeroing, etc.

IO output

1 channel, determines status of output.

Power voltage

DC12-24V±10%

Power consumption

60mA or less (DC 12V).120mA or less (DC24V)

Operating temperature

-10-50oC

Storage temperature

-20-70oC

Working humidity

35%-85% no condensation or frost

ESD protection

Contact discharge 4kV, air discharge 8kV, conforms with IEC61000-4-2 standard

EFT protection

Power port 2kV/5 or 100kHz, signal port 1kV/5 or 100kHz, conforms with IEC61000-4-4

Bumps

500m/s2(approx. 50G), 3 times along the X, Y, and Z axes

Vibrations

10-55Hz, double amplitude 1.5mm along X, Y, and Z axes for 2 hours

IP level

IP67, conforms with IEC 60529 standard

Dimensions (mm)

60×50×22

Weight (Including cables)

120