SD33-30-485-VA

SD33-30
SD33-30
SD33-30
  • SD33-30
  • SD33-30
  • SD33-30

SD33-30

Product Introduction

Integrated body, simple setting, light outlet and receiving area using glass lenses, better temperature resistance, light transmission, corrosion resistance


Download related documents
Contact Now price

Technical specifications

Model

SD33-30-485-VA

Reference distance (RF)

30mm

Measuring range

±4mm

Light source

Light source wavelength

655nm

Laser class

Class II

Laser output power

1mW

Laser point diameter (Laser dot size)

Near-end

80*180μm

Reference distance

70*260μm

Far-end

100*400μm

Repeatability

2μm

Linearity

±0.05% F.S.

Temperature characteristics

0.05% F.S./℃

Sampling refresh rate (Hz)

500/1000/2000/3000Hz (Choose from four levels)

I/O

Communication port

1 RS485

Analog output

1 channel analog output, analog voltage (0~10V) or analog current (4~20mA)

Analog voltage or current cannot be switched

IO input

1 channel, supports functions, such as laser shutdown, remote teaching, sampling and holding, single-pulse trigger, zeroing, etc.

IO output

1 channel, determines status of output.

Power voltage

DC12-24V±10%

Power consumption

60mA or less (DC 12V).120mA or less (DC24V)

Operating temperature

-10-50oC

Storage temperature

-20-70oC

Working humidity

35%-85% no condensation or frost

ESD protection

Contact discharge 4kV, air discharge 8kV, conforms with IEC61000-4-2 standard

EFT protection

Power port 2kV/5 or 100kHz, signal port 1kV/5 or 100kHz, conforms with IEC61000-4-4

Bumps

500m/s2(approx. 50G), 3 times along the X, Y, and Z axes

Vibrations

10-55Hz, double amplitude 1.5mm along X, Y, and Z axes for 2 hours

IP level

IP67, conforms with IEC 60529 standard

Dimensions (mm)

60×50×22

Weight (Including cables)

120