Silicon Rod Size Detection in Silicon Wafer Manufacturing
Silicon rods are widely used in the field of solar cell manufacturing due to their excellent performance. After the silicon rods are manufactured, they may have defects such as external cracks, voids, bubbles, internal impurities, etc., so strict quality control tests are required before they can be used in subsequent production.
Common challenges include:
· Defects in Silicon Rods: Issues such as cracks, voids, bubbles, and impurities can compromise product performance and lead to production inefficiencies.
· Dimensional Accuracy: Precise measurement of size, arc length, and verticality is required to meet strict industry standards.
· Comprehensive Quality Control: Traditional methods often lack the precision and efficiency needed for high-volume inspections.
SinceVision Solution: SR7060 3D Laser Profiler
Camera Selection
Model number | SR7060 | |||
Reference distance (CD) | 80mm | |||
Measuring range | Z-axis height (FS) | 9.5 mm | ||
X-axis width | Near side | 41.5 mm | ||
Reference distance | 44mm | |||
Remote side | 46.5 mm | |||
Light source | Light source wavelength | 405nm blue light | ||
Laser class | 2M | |||
Laser output power | 10mW | |||
Repetition accuracy | Z-axis (height) | 0.3μm | ||
X-axis (width) | 4 μm | |||
linearity | Z-axis (height) | ±0.05% F.S. | ||
Contour data interval | X-axis (width) | 15 microns | ||
X-axis contour points | 3200 | |||
Reflection Angle (°) | 30 | |||
Scanning speed (Hz) | 2500 ~ 10000 | |||
Dimension (mm) | 156×97.5×55 | |||
Weight (g) | 750 | |||
Temperature characteristic | 0.02% F.S./℃ | |||
Encoder input | Single-ended, differential encoder is supported | |||
Input/output | 1 RS232 interface, 1 100Base-TX/1000Base-T Ethernet interface | |||
Operation Temperature | 0~50℃ | |||
Storage Temperature | -20~70℃ | |||
Working Humidity | 35% to 85% without condensation | |||
ESD Protection | Contact discharge 4kV, air discharge 8kV, in accordance with IEC 61000-4-2 standards | |||
EFT protection | Power port 2kV/5 or 100kHz, signal port 1kV/5 or 100kHz, in accordance with IEC 61000-4-4 standards | |||
Impact | 50Gs/3ms per axis, in accordance with IEC 68-2-27 Ea standard | |||
Vibration | 10Gs (10-500Hz), compliant with IEC 68-2-6 Fc standard | |||
degrees of protection provided by enclosure | IP67, in accordance with IEC 60529 standard |