EXV Weld Inspection for Automotive Valve Bodies with SinceVision SR7020 3D Laser Profiler
Industry pain points and demands
Inaccurate or defective welding on the valve body of an EXV can lead to operational failures and reduced product reliability. Ensuring high-precision welding inspection is critical to maintaining the performance and safety of automotive systems.
Physical Picture or Imaging Effect Picture
SinceVision Solution: SR7020 3D Laser Profiler
01High Accuracy: Achieves 0.01MM repeatability to detect the smallest welding defects.
02Enhanced Quality Control: Optimizes weld integrity and ensures safety standards.
03Industry-Specific Design: Tailored for automotive valve body applications.
Camera Selection
Model number | SR7020 | |||
Reference distance (CD) | 23mm | |||
Measuring range | Z-axis height (FS) | 3.8mm | ||
X-axis width | Near side | 9.2mm | ||
Reference distance | 9.6mm | |||
Remote side | 9.6mm | |||
Light source | Light source wavelength | 405nm blue light | ||
Laser class | 2M | |||
Laser output power | 10mW | |||
Repetition accuracy | Z-axis (height) | 0.1μm | ||
X-axis (width) | 1.0μm | |||
linearity | Z-axis (height) | ±0.05% F.S. | ||
Contour data interval | X-axis (width) | 3μm | ||
X-axis contour points | 3200 | |||
Reflection Angle (°) | 41.5 | |||
Scanning speed (Hz) | 750 ~ 2000 | |||
Dimension (mm) | 125×82×55 | |||
Weight (g) | 690 | |||
Temperature characteristic | 0.02% F.S./℃ | |||
Encoder input | Single-ended, differential coders are supported | |||
Input/output | One 100Base-TX/1000Base-T Ethernet interface | |||
Operation Temperature | 0~50℃ | |||
Storage Temperature | -20~70℃ | |||
Working Humidity | 35% to 85% without condensation | |||
ESD Protection | Contact discharge 4kV, air discharge 8kV, in accordance with IEC 61000-4-2 standards | |||
EFT protection | Power port 2kV/5 or 100kHz, signal port 1kV/5 or 100kHz, in accordance with IEC 61000-4-4 standards | |||
Impact | 50Gs/3ms per axis, in accordance with IEC 68-2-27 Ea standard | |||
Vibration | 10Gs (10-500Hz), compliant with IEC 68-2-6 Fc standard | |||
degrees of protection provided by enclosure | IP67, in accordance with IEC 60529 standard |