Mouse Gap Width Detection: Ensuring Precision with 3D Laser Profilers
In the consumer electronics sector, the craftsmanship of a mouse significantly impacts user experience. A well-designed mouse with appropriately positioned buttons enhances sensitivity and responsiveness, which is crucial for gaming and productivity. However, ensuring the assembly quality of mice can be challenging. Inaccurate gap widths between mouse buttons and the scroll wheel can lead to functionality issues and customer dissatisfaction.
To address these challenges, SinceVision employs the SR9061 3D Laser Profiler to detect the gap width between mouse components accurately. This advanced technology features a large field of view and depth of field, eliminating the need for multi-segment scanning. As a result, manufacturers can achieve higher detection efficiency while maintaining quality standards.
Physical Picture or Imaging Effect Picture
SinceVision Solution: SR9061 3D Laser Profiler
Camera Selection
Model number | SR9061 | |||
Reference distance (CD) | 60mm | |||
Measuring range | Z-axis height (FS) | 14.5mm | ||
X-axis width | Near side | 25mm | ||
Reference distance | 27mm | |||
Remote side | 30mm | |||
Light source | Light source wavelength | 405nm blue light | ||
Laser class | 2M | |||
Laser output power | 10mW | |||
Repetition accuracy | Z-axis (height) | 0.2μm | ||
X-axis (width) | 1.2μm | |||
linearity | Z-axis (height) | ±0.02% of F.S. | ||
Contour data interval | X-axis (width) | 5μm | ||
X-axis contour points | 6400 | |||
Reflection Angle (°) | 30 | |||
Scanning speed (Hz) | 1500 ~ 13000 | |||
Dimension (mm) | 176×126×67 | |||
Weight (g) | 2050 | |||
Temperature characteristic | 0.02% F.S./℃ | |||
Encoder input | Single-ended, differential encoder is supported | |||
Input/output | One 100Base-TX/1000Base-T Ethernet interface | |||
Operation Temperature | 0~50℃ | |||
Storage Temperature | -20~70℃ | |||
Working Humidity | 35% to 85% without condensation | |||
ESD Protection | Contact discharge 4kV, air discharge 8kV, in accordance with IEC 61000-4-2 standards | |||
EFT protection | Power port 2kV/5 or 100kHz, signal port 1kV/5 or 100kHz, in accordance with IEC 61000-4-4 standards | |||
Impact | 50Gs/3ms per axis, in accordance with IEC 68-2-27 Ea standard | |||
Vibration | 10Gs (10-500Hz), compliant with IEC 68-2-6 Fc standard | |||
degrees of protection provided by enclosure | IP67, in accordance with IEC 60529 standard |