Cell Hot Pressure Monitoring in Lithium Battery Production Using SinceVision's Laser Displacement Sensor
In lithium battery production, cell hot pressing shaping plays a critical role in ensuring structural integrity. During the process, parameters like pressure, pressure time, and template temperature must remain stable to prevent issues like powder loss or fractures when the cell bends. The SinceVision SD33-50 Laser Displacement Sensor is used to continuously monitor the stroke and bottom dead center of the hot press, providing real-time feedback to the upper computer. This ensures accurate pressure drop measurement and optimal process control, making it an essential tool for maintaining quality in automobile and lithium industries.
SinceVision Solution: SD33-50 Laser Displacement Sensors
Camera Selection
Model number | SD33-50-485-VA | ||
Reference distance (CD) | 50mm | ||
Measuring range | ±10mm | ||
Light source | Light source wavelength | 655nm | |
Laser class | Class 2 | ||
Laser output power | 1mW | ||
Spot diameter (spot size) | Proximal end | 120 * 230 microns | |
Reference distance | 110 * 440 microns | ||
Distal end | 150 * 670 microns | ||
Repetition accuracy | 5 microns | ||
linearity | ±0.1% F.S. | ||
Temperature characteristic | 0.05% F.S./℃ | ||
Sampling frequency (Hz) | 500/1000/2000/3000Hz(4 levels optional) | ||
Input/output | Communication port | 1 RS485 (support ModbusRTU) | |
Analog output | 1 analog output, analog voltage (0~10V) or analog current (4~20mA) Analog voltage or analog current cannot be switched | ||
IO input | 1 channel, support laser shutdown, remote teaching, sampling hold, single pulse trigger, return to zero and other functions | ||
IO output | 1 route, determine the status output | ||
Operating temperature | -10 ~ 50℃ | ||
Storage temperature | -20 ~ 70℃ | ||
Working humidity | 35% to 85% no condensation | ||
EFT protection | Power port 2kV/5 or 100kHz, signal port 1kV/5 or 100kHz, in accordance with IEC 61000-4-4 standards | ||
ESD protection | Contact discharge is 4kV and air discharge is 8kV, in line with IEC 61000-4-2 standards | ||
Vibration | 10~55Hz, dual amplitude 1.5mm, 2 hours in X, Y, and Z directions respectively | ||
Impact | 500m/s ² (approximately 50G), 3 times in X, Y, and Z directions respectively | ||
IP level | IP67, in accordance with IEC 60529 standard | ||
Size (mm) | 60*50*22 | ||
Weight (including cables) | 120g |